Green Air CDMC-7 CO2 Monitor Controller CDDS-2 & CDM-7001 Sensor
Green Air CDDS-2 & CDM-7001 Sensor Model CDMC-7
CARBON DIOXIDE MONITOR CONTROLLER SYSTEM
CDMC-7
This CO2 monitor control system functions exactly like the CDMC-6 system and utilizes the same controller (sequencer) CDDS-2. However, the CDM-7001 monitor in this system offers the versatility of portability. You can detach to the monitor and carry it from one location to the next and make spot checks of CO2 concentrations. Please note that the monitor must be patched into the controller to actually enrich or vent CO2.
 |
FEATURES
• Built-in Photo Sensor for enhanced control • Easy to program and operate with adjustable hysteresis (differential) • Programmed for overshoot protection logic • Portable CO2 monitor display both CO2 levels and temperature • Durable infrared sensor • CO2 measurement range from 0-5000 PPM • CO2 control range from 300-5000 PPM • Easy to read LED display light will not affect plant growth • Mode indicator LEDs • Factory calibrated and inspected for precision performance • Operates on 120 VAC at 60 Hz, 12 Amp switching capacity • Built in kick-stand • Requires 4 AAA batteries for portable operations • CO2 gas calibration port • Manufactured in Oregon, USA
|
The CDMC-7 system is designed to sample the air and learn the characteristics of your space, then make adjustments as necessary to ensure a constant level of CO2. The CDM-7001 works in conjunction with the CDDS-2 controller (sequencer) to effectively enrich indoor gardens and greenhouses with CO2 or reconfigured the system mode to vent excess CO2 if desired.
ENRICHMENT or VENTING MODE
The CDMC-7 can be used to operate CO2 producing (enrichment) equipment or CO2 venting (exhaust) equipment. Use the MODE button to quickly and easily switch between enrichment or venting functions. The venting mode is useful for evacuating accumulated CO2 in hospitals, class rooms, factories, conference and meeting rooms, offices, laboratories and mushroom culture facilities.
HOW THE CDMC-7 SYSTEM WORKS
The CDM-7001 samples the air then sends the sample data to the CDDS-2. The CDDS-2 then activates or deactivates your CO2 enrichment or CO2 venting (exhaust) equipment as necessary to maintain CO2 PPM based on your set point. For best results, turn off all exhaust functions and close all doors and windows during the initial 24-hour adjustment period. You must allow this 24-hour adjustment period, every time you relocate the system to a new space. After 24 hours, you can restart your exhaust functions and continue as normal.
OVERSHOOT PROTECTION LOGIC
In enrichment mode, the CDDS-2 employs a sophisticated adaptive algorithm “Overshoot Protection Logic” which learns the dynamics of the space being controlled. This allows the system to avoid dramatic overshoots inherent to set point controllers or timed CO2 enrichment. These learned parameters are stored in memory, even when the ‘POWER’ is off, until you reset the CDDS-2.
The graph below demonstrates the average variance in CO2 concentrations when using the CDMC-7 system with “Overshoot Logic Protections” verses timed CO2 enrichment.
Example: Enrichment Mode Set Point = 1050 Hysteresis = 50
If you have any questions, feel free to ask.
Shipping & Handling is Free for this item
Hawaii, Alaska, and International shipping will be Extra.
Please email us for a international shipping quote - Service@aqualightsonline.com
Manufacturer: Green Air
SKU: 703420